Structural and Foundation
STRUCTURAL
Loads
Roof Framing Plan
Outside Units Framing
FOUNDATION
Main Building Foundation
Outside Units Foundation
Building B-D
Building E
Building F
- Framing system
- Foundation
- Materials
- Steel (HR & CF)
- Reinforced Concrete
- CMU
- Adherence to building codes
- IBC 2015
- ASCE 7-16
- AISC 15th Edition
- ACI 318-14
- SJI 100-2015
- San Antonio Unified Development Code
- Loads Calculations
Loads
- Floor:
- Live 125 lb/ft² , light storage ASCE 7-16
- Dead 80 lb/ft², found analytically based dead weights
- Roof:
- Live 20 Psf
- Dead 16 lb/ft²
- Snow = 1.89 lb/ft²
- Envelope Method
- Wind Load Controlling = -24.06
- Exposure Cat C
Main Building Framing
- Steel Girder (W-Shapes)
- Vulcraft Steel Joist
- HSS Steel Columns
- Connections
- Double Angle All Bolted (W to HSS)
- Bearing Plate & Welded Seat (Joist to W)
- Built-Up Angle & Plate (Joist to HSS)
- Welded Gusset Plate (X- Brace)
- Steel Base Plates for Column
Roof Framing Plan
Outside Units Framing
- Light Building Units
- Prefabricated with thin metal sheets
- Lateral Bracing Design
- Cee Channel metal studs
- Compression Members
- Cee Channel metal studs
- Flexural Members
- Zee Purlins.
- Connections using metal plates using #12 screws.
FOUNDATION
Main Building Foundation
Outside Units Foundation
Building B-D
Building E
Building F